YOUR STAND DETAILS
Please refer to your Stand Agreement to confirm whether you have a Premium Shell Scheme, Pavilion or Floor Space Only Stand.
SHELL SCHEME STAND PACKAGE INFORMATION
IF YOU ARE PARTICIPATING AS PART OF A PAVILION PLEASE CHECK WITH YOUR PAVILION HEAD TO CONFIRM YOUR STAND PACKAGE INCLUSIONS AS A CUSTOM PACKAGE MAY HAVE BEEN ARRANGED.

SHELL SCHEME – OPTION A
SHELVING (4 metres)

SHELL SCHEME – OPTION B
IN-BUILT CLOTHES RAILS (2 metres)
| Walls |
|
| Fascia Signage |
|
| Lighting |
|
| Power |
|
| Flooring |
|
| Furniture |
|
| Display Accessories | One of the following options:
|
Adhesives to use on walls: Velcro, bluetac, double-sided adhesive tape or wall-mounted shelving and hooks, all are available from ExpoNet if required. Walls cannot be screwed into.
Adhesives NOT to be used on walls: Pins, staples, screws, nails, bolts, glue and paint will permanently damage the Panels. Charges will apply to Exhibitors who damage wall surfaces.
STAND AND FASCIA SIGNAGE
To confirm the company name to be displayed on your stand fascia signage above your stand, please complete the Fascia Confirmation Form in the Forms Section of the Online Exhibitor Manual before Friday 16 October 2026. Note that a maximum of 30 characters can be printed per sign. Pty Ltd etc. will be deleted. Names will be printed in uppercase.
For Exhibitors participating as part of a Pavilion, please be advised that we will also check your stand signage requirements with the head of your Pavilion /Booking Agent.
ADDITIONAL ITEMS
ExpoNet is the official Stand Builder. If you require additional lighting, power, signage or furniture, you must order before Friday 16 October 2026. Please refer to the ExpoNet Order Forms in the Forms Section of the Online Exhibitor Manual.
Alternatively, you can contact the Exhibitor Services Department via email sourcing@exponet.com.au or tel +61 3 9676 7777.
FLOOR SPACE ONLY STANDS
All custom-built stands require approval prior to Move In. Stand plans and confirmation that the wall system erected is self-supporting must be submitted to the Organiser by Friday 16 October 2026. Please email all plans and documentation to carly.molnar@ie-group.com.au
If you require assistance finding a suitable Contractor, please refer to the Key Contacts List.
Stand Plans
All plans and documentation should be in English and must show the scale used (at least 1:50). They should clearly state:
- The exhibiting company’s name and stand number
- The name and contact number of the responsible contractor
- Details of dimensions, layout, position of exhibits and storage/office areas
All plan submissions should also include: all stand dimensions including height, stand orientation within the Exhibition Hall with an indication of which sides are open onto aisles, details of all walling, raised floors, demonstration areas, exhibits, graphics etc.
Floor Space Only Exhibitors are required to provide:
Lighting & Power
Your stand will require lighting and may require power. Additional lighting helps to highlight special features within your stand area. All lighting must be 2.2 metres above the floor level and any variations must have prior approval of the Venue. High powered lights such as floods or spots must not be placed within 500mm of flammable material. All portable light fittings must have a Certificate of Suitability or a Certificate of Approval from Australian or New Zealand Electrical Safety Regulators.
If unsure, please contact ExpoNet via email at sourcing@exponet.com.au
Testing & Tagging – Australian Standards
It is a legal requirement in Temporary Exhibition Work Sites that all electrical equipment be tested and tagged in accordance with SAA 300 Wiring Rules and Code of Practice for Temporary Installations under the OH&S Act 2000. Random checks will be carried out to ensure all equipment onsite within the Venue meets with Australian Standards. Non-compliance will result in the owner of the equipment being asked to remove the equipment.
Flooring
The Melbourne Convention & Exhibition Centre is not carpeted therefore you are responsible for providing your own flooring. All stands with raised floors require a bevelled edge. All raised floors, steps and ramps within exhibits must comply with the relevant sections of the Building Code of Australia. Any raised floor sections must be clearly distinguishable from areas of the surrounding floor space.
All raised floors with a height of less than 115mm are not regarded as a step, and these floors will require a suitable and clearly distinguishable ramp from the main exhibition floor level or surrounding platform to the raised section. The ramp must be of a gradient no less than 1 to 3 and be contained within the contracted space. Ramps may not protrude into the nominated aisle way, so must be included in the stand space. The only exception to this requirement is for ramping on 32mm raised flooring constructed from one
(1) metre modular floor sections, where an allowance of up to 100mm intrusion into the aisle will be acceptable and the 1 to 3 gradient will be maintained.
All raised floors with a height greater than 115mm but less than 190mm from the main exhibition floor level or surrounding platform will be regarded as a step and generally will not require a ramp. However, an approved stair nosing must be installed as per requirements for steps in public places. The raised floorsections or ramps must not contain sharp or dangerous edges and must not cause a trip hazard. Disabled access to the stand must be provided.
Walls
Any wall must be built to a height of 2.5 metres. If your walls and/or displays are to exceed 2.5 metres i.e. the standard Pre-Built stand wall height, consent must first be obtained in writing from the Organiser. If the wall height exceeds 2.5 metres the back of your wall adjacent to the adjoining Exhibitor, must be appropriately dressed. If your stand does not adjoin another Exhibitor, all walls must be appropriately dressed. NOTE: The maximum permitted height of any wall is 3 metres.
Signage
Signs, banners and similar materials may not be nailed, stapled, hung or attached to the ceilings, walls, windows, sprinkler systems or any other surface of the Venue, except by permission of the Venue. Damage resulting from installation will be a direct charge to the Exhibitor.
Additional Safety Precautions
Should your exhibit feature any of the following items listed contact the Organiser via sourcingadmin@ie-group.com.au for further information on the safety steps you may need to take or written approvals that you may need to gain: a second storey, a solid ceiling/roof area more than 18sqm, a structure more than three (3) metres high, naked flame (e.g. a candle), lighting lower than 2.2m above floor level. All portable light fittings used in the Venue are required to have Certificate of Approval or Suitability from an Australian or New Zealand Electrical Safety Regulator.